Rated input: 1000mA
Rated output: 0.5mA
Core-through hole diameter: Φ35, Φ80, Φ120
Rated input: 100 - 900A
Rated output: 5A
Core-through hole diameter: Φ23, Φ45, Φ65, Φ80, Φ100
Voltage grade: 220V
Main functions: Monitoring and real time reporting of collection point residual current, mainly used for monitoring whether there is any leakage point at factory collection points
Main features: High precision, convenient installation, good safety and high reliability
Applicable occasion: factory gate points and transformer outgoing terminal
Voltage grade: 220V
Communication mode: Uplink: 4G,downlink: infrared
Installation mode: Adsorption type mounting
Main functions: Convenient installation, stable data transmission, long infrared effective distance, and support for various electricity meter protocols
Main functions: collection of data of various electricity meters at gateways, monitoring of electricity meters in real time, demand reporting, etc.
Voltage grade: 100/220V(optional)
Main features: Acquisition speed block, high reliability, large storage capacity and good openness
Communication mode: Uplink: 4G,downlink: RS485, LoRa, local parameter configuration: IR
Main functions: Remote meter reading, time calibration function, self-diagnosis function, re-reading and alarm of un-read data, data statistics analysis and storage, and single-point uploading
Voltage grade: 220V
Communication mode: Uplink: 4G,downlink: RS485, LoRa, local parameter configuration: IR
Main features: Remote meter reading, time calibration function, self-diagnosis function, re-reading and alarm of un-read data, data statistics analysis and storage
Voltage grade: 220V
Communication mode: Uplink: LoRa, downlink: 4G
Main features: LoRa (remote) spread spectrum technology, half duplex communication and super anti-interference
Main functions: Unvarnished transmission and forwarding, running, working status and other indicators, and display of communication status
Voltage grade: 3*57.7V
Specification: three-phase four-wire
Installation mode: Wall-mounted
Data collection: Basic measurement, power metering, demand monitoringApplicable occasion: High-voltage gateway metering, demand forecast, demand alarm, etc.
Voltage grade: 3*57.7V
Specification: Three-phase-four wire
Installation mode: Rail guide type
Data collection: Basic measurement, power metering, power quality and demand monitoringApplicable occasion: High voltage gateway side of the factory, used for power use monitoring, demand forecasting, demand alarm at gateway metering points
Voltage grade: 3*100V
Specification: Three-phase three-wire
Installation mode: Wall-mounted
Data collection: Basic measurement, power metering, demand monitoringApplicable occasion: Metering at high-voltage gateways, demand forecast and demand alarm, etc.
Voltage grade: 3*220V
Specification: three-phase four-wire
Installation mode: Embedded in panel
Data collection: Basic measurement, power metering, power quality, demand monitoringApplicable occasion: High voltage gateway side of the factory, used for power use monitoring, demand forecasting, demand alarm at gateway metering points
Voltage grade: 3*100V
Specification: Tree-phase three-wire
Installation mode: Panel-embedded
Data collection: Basic measurement, power metering, power quality and demand monitoringApplicable occasion: All the low-voltage sides of the factory, including transformer secondary side, workshop, equipment side and other metering points of power use monitoring
Voltage grade: 3*220V
Specification: Three-phase four-wire
Installation mode: Guide rail type
Data collection: Basic measurement, power metering, power quality and demand monitoringApplicable occasion: All the low-voltage sides of the factory, including transformer secondary side, workshop, equipment side and other metering points of power use monitoring